Ⅰ. Product Introduction
The TAM series of Tritium Air Monitors are comprised of mains unit and ionization chambers. Main unit is a SCM System based on 8031 sing chip system. These Tritium Air Monitors are designed to have a wide variety of features, including automatic control, automatic zero setting, multi-parameter display, data monitoring, processing and storage, and warning and communication. By employing modular design, this series of Monitors provide optional installation and combination suitable for automatic continuous air monitoring for the presence of tritium in the environment, glove box at nuclear facilities, highly radioactive noble gases and in a wide range of situations.
Type | TK-C200 Air tritium monitor | TK-C400 Wide range air tritium monitor | TK-C600 Identification type air tritium monitor |
Detector | Four cylindrical silk wall ionization chambers with gamma differential compensation, each with effective volume of 2 L | Silk wall ionization chambers, each with effective volume of 1 L | Gas-flow ionization chamber for beta, radon, alpha measurement |
Range | 40 Bq/L﹣8.0×107 Bq/L | 2×102 Bq/L﹣2×1010 Bq/L | 0.01﹣105 Bq/L |
Precision | Relative error≤5% Coefficient of variance ≤2% | Relative error≤20% Coefficient of variance ≤2% | Intrinsic error≤±10% |
Response time | Adjustable, recommended as 5 min for environmental monitoring | Automatically adjustable within 3-30s | 15min |
Discrimination | — | — | compensation coefficient ≥95% |
Alarm threshold | Configurable setting within range | ||
Communication Interface | RS-485 standard interface, baud rate 19200 bps | ||
Total weight | 20 kg(TAM-500: 75 kg), detector unit: 15 kg,main unit: 1.25 kg | ||
Power supply | AC 220 V ±10%,50Hz ±10%,power dissipation ≤ 6 W | ||
Operating environment | temperature: 0℃﹣50℃, relative humidity: 10%﹣90% at 35℃ |
Ⅱ. Technical Specifications
No. | Item | Parameter |
1 | sensitivity | 1μCi/m3(0.05DAC) |
2 | Accuracy | ±0.1μCi/m3 from 1 to 100μCi/m3, ±10% from 100μCi/m3 to 20000μCi/m3 or better |
3 | Range | 1μCi/m3 to 199,999μCi/m3 |
4 | Detector
| 4 matched chambers. two for measuring and two for compensation |
5 | Measuring chamber effective volume
| 4000cc (2measuring chambers of 2000 cc each)
|
6 | Flow rate | 1.0 L/min |
7 | Zero stability | ±0.1μCi/m3 immediately after unit is powered on or better |
8 | Background cancellation | Very effective and efficient background cancellation of gamma(all energies) radon and noble gases is required. |
9 | Compensation | Radon compensation should be included in the software beta other than tritium ,gamma and noble gases compensation is very essential |
10 | Ion trap | have |
11 | Dust filter | replaceable easily |
12 | Noble gas cancellation | No
|
13 | Tritium discrimination | Instrument can discriminate in a field |
14 | Purge/decontamination | Detective unit made by New structure ,very low tritium remember effect. |
15 | Display | Graphic touch screen LCD display .unit displays the values |
16 | Communication | RS485 |
17 | Power supply | 220V AC |
18 | Alarm | Tritium alarms gamma alarms low air flow alarms will all be shown by red LED light and by an audible device |
19 | Data logging | The tritium and gamma values at logged every minute with current time and date stamp |
20 | Response time | a) seconds~2min(see tritium readings ) |
Ⅲ. Applications
Nuclear power plant
Nuclear research